Remembering Brackenridge 1991 Floor Collapse and LODD

12-21-2009 9-53-23 PMRemembering Brackenridge, Pennsylvania December 20, 1991: Four Firefighters Killed, Trapped by Floor Collapse

Four volunteer firefighters died when they were trapped by a partial floor collapse during a structure fire in Brackenridge, Pennsylvania, on the morning of December 20, 1991. All four were members of a mutual aid truck company that had responded to the early morning incident and were assigned to prevent fire extension from the basement to the ground floor of a 2-story building. Although they were wearing full protective clothing and using self-contained breathing apparatus, it appears that they were overwhelmed by the severe fire conditions that erupted when a section of the ground floor collapsed into the basement. The collapse cut off their primary escape path, and the fire burned through their hose line, leaving them without protection from the flames.  

 SUMMARY OF KEY ISSUES

  • Situation: Fire in enclosed room in basement. Unable to locate fire because of smoke. Smoke and heat increasing, but no visible fire.
  • Structure: Appeared to be heavy concrete construction. Actually thin concrete floors supported by unprotected steel.
  • Contents: Furniture refinishing business. Quantities of flammable finishes and solvents in basement.
  • Exits: One entrance/ exit on each level; no alternate exits.
  • Structural Collapse: Floor section collapsed between interior crew and their only exit. Fire overwhelmed crew.
  • Rescue Attempts: Valiant rescue efforts proved unsuccessful. Unsure if missing members fell into basement or were trapped on ground floor.
  • Incident Command: No formal command system or personnel accountability in place. Chief of first-due company in command of incident; Assistant Chiefs assigned to basement and ground floor.
  • Information: No pre-fire plan and no detailed knowledge of occupancy. Clues of structural danger not recognized as fire conditions increased
  • Communications: Radio system inadequate for current needs.
  • Response: Independent volunteer companies. Mutual aid requested on arrival and additional companies called in succession.
  • Weather: Extremely cold night, predawn hours. Problems with frozen hydrants.
  • Water System: Weak supply. Extensive mutual aid and long relays needed to protect exposures.

The analysis of this incident provides several valuable lessons for the fire service. Unfortunately these are all revisited lessons, not new discoveries. These firefighters died in the line of duty, while conducting operations that appeared to be routine, and were unaware of the situation that was developing below them. They died in spite of the fact that they were experienced, they were operating with a standard approach to operational safety, and they were the object of repeated rescue attempts by highly capable comrades.

There are several factors that could have provided warning or changed the outcome of this situation. Like most accidents, this situation was the result of a number of problems that came together under the worst possible circumstances. Firefighting obviously involves inherent dangers that must be accepted by its practitioners. The important messages for the fire service are to identify risk factors in advance of an incident and to develop mechanisms to react appropriately when critical situations present themselves.

This situation bears distinct similarities to other incidents that have claimed the lives of several firefighters in the past. The lessons that must be derived from this incident are not a condemnation of the actions or judgment of anyone who was involved in the situation; they simply identify information that can help to prevent this type of accident from occurring in the future.

USFA Report; HERE

NFPA Summary; HERE

NFPA Report Order; HERE 

Brackenridge Pioneer Hose Co. Memorial, Pennsylvania, HERE

1 Comment

3 Trackbacks

Leave a Reply

Your email address will not be published. Required fields are marked *

background image Blogger Img

Chris Naum

Welcome to Commandsafety.com. The authoratative and informational site that provides leading insights on fire service issues related to Building Construction, Command Risk Management and Firefighter Safety.

Christopher Naum's Discussions

/* Removes Buzzboost Logo (MBT) */ div #creditfooter{ display: none; }
Follow Chris Naum

Mission Critical

banner ad

banner ad

FirefighterNetCast on Blog Talk Radio

Listen to internet radio with FirefighterNetCast on Blog Talk Radio

The Tombs

The New Safety Formula: Bk = F2S

Without understanding the building-occupancy relationships and integrating; construction, occupancies, fire dynamics and fire behavior, risk, analysis, the art and science of firefighting, safety conscious work environment concepts and effective and well-informed incident command management, company level supervision and task level competencies…You are derelict and negligent and "not "everyone may be going home". Our current generation of buildings, construction and occupancies are not as predictable as past conventional construction; risk assessment, strategies and tactics must change to address these new rules of structural fire engagement. There is a need to gain the building construction knowledge and insights and to change and adjust operating profiles in order to safe guard companies, personnel and team compositions. It's all about understanding the building-occupancy relationships and the art and science of firefighting, Building Knowledge = Firefighter Safety (Bk=F2S)

Addressing Today’s Evolving Fireground

Lectures,Seminars and Training Programs

banner ad

Taking it to the Streets Radio

  • banner ad
  • The Newest radio show on FireFighter Netcast.com at Blogtalk Radio… Taking it to the Streets with Christopher Naum. On the Air Monthly on Firefighter Netcast.com. A Buildingsonfire.com Series and Firefighter Netcast.com Production. Advancing Firefighter Safety and Operational Integrity for the Fire Service through provocative insights and dynamic discussions dedicated to the Art and Science of Firefighting and the Traditions of the Fire Service.

QR Code for Commandsafety.com

qrcode

Categories

FireEMS Blogs eNewsletter

Sign-up to receive our free monthly eNewsletter

LATEST FIREFIGHTER NEWS

HOT FORUM DISCUSSIONS

LATEST ON FIRE ENGINEERING

FEATURED DISCUSSIONS