Effective Battle Plans & Performance

The following are quotes from Fire Chief Anthony Aiellos (ret) Hackensack (NJ) Fire Department, Fire Chief during the Hackensack Ford Fire, July, 1988…

“If you don’t fully understand how a building truly performs or reacts under fire conditions and the variables that can influence its stability and degradation, movement of fire and products of combustion and the resource requirements for fire suppression in terms of staffing, apparatus and required fire flows, then you will be functioning and operating in a reactionary manner.”

“This places higher risk to your personnel and lessens the likelihood for effective, efficient and safe operations. You’re just not doing your job effectively and you’re at RISK. These risks can equate into insurmountable operational challenges and could lead to adverse incident outcomes. Someone could get hurt, someone could die, it’s that simple, it’s that obvious.”

Risk Based Response Assignments
The buildings, structures and occupancies that comprise typical response districts pose unique and consistent challenges during structural fire attack. The variety of occupancies and building characteristics establish varying degrees of risk potential, with defined and recognizable strategic and tactical measures to be taken-sometimes uniquely to each occupancy type. Although each occupancy type presents variables that dictate how a particular incident is handled, most company operations evolve from basic principles rooted in past performance and operations at similar structures. This is based on what I define as; “predictability of performance.”

When we look at various buildings and occupancies, past operational experiences; those that were successful, and those that were not, give us experiences that define and determine how we access, react and expect similar structures and occupancies to perform at a given alarm in the future. Naturalistic (or recognition-primed) decision-making forms much of this basis. We predicate certain expectations that fire will travel in a defined (predictable) manner that fire will hold within a room and compartment for a given duration of time, that the fire load and related fire flows required will be appropriate for an expected size and severity of fire encountered within a given building, occupancy, structural system.

We used to know with a measured degree of predictability, how our buildings would perform, react and fail under most fire conditions. This is what our years of fireground experience provided us, and how we ultimately would predict, assess, plan and implement our incident action plans and ultimately deploy our companies-based upon the predictable performance expected. Conventional Construction Structures (CCS) had this “predictably of performance.” You know, that typical residential structure, the 2-1/2 story wood frame, the three story brick and joist type III occupancy, the four story frame multiple occupancy, etc., etc.

Unlike Engineered System Structures (ESS) whose predictability is rooted in the fact that they are unpredictable.The emerging fire service issues affecting buildings, occupancies and structural systems related to ESS is only beginning to take hold a prominent role and level of significance that is long overdue. The fire service has been dealing with the operational issues and line-of-duty deaths related to ESS since the 1980s and now in 2009, we’re finally raising these ESS issues to a dialog point that is influencing firefighter safety, survival and operations. ( Refer to the Underwriters Laboratory’s (UL) UL University on-line training module for a state-of-the art presentation on Structural Stability of Engineered Lumber in Fire Conditions and performance results that correlate towards redefining fire suppression operations)

The fire service is beginning to fully recognize the merits in adjusting, altering, and changing our strategic and tactical ways of doing business in the streets. It’s becoming self evident in the fire service that it’s no longer acceptable to think that ESS buildings and occupancies will perform in the same manner as CCS buildings and occupancies and that tactics deployed in both CCS and ESS buildings and occupancies will react under similar strategic and tactical plans and tasks. These unique and inherent factors within the ESS profiles must give us a new standard for operational deployment; strategies and tactics that are defined by the risk profile of the building, its engineered structural systems, materials and methods of construction and the fire loading present.

Considerations for changing fire flow rates, the sizing of hose line and the adequacies for fire flow demand and application rates, staffing needs for safe operations, considerations for defensive positioning and defensive operating postures must be considered, and it warrants repeating again; Reckless-Aggressive firefighting must be redefined in the built environment and associated with goal oriented tactical operations that are defined by risk assessed and analyzed tasks that are executed under battle plans that promote the best in safety practices and survivability within know hostile structural fire environment- with determined, effective and proactive firefighting.

1 Trackback

Leave a Reply

Your email address will not be published. Required fields are marked *

background image Blogger Img

Chris Naum

Welcome to Commandsafety.com. The authoratative and informational site that provides leading insights on fire service issues related to Building Construction, Command Risk Management and Firefighter Safety.
Categories
  • "firefighter safety" (126)
  • "health and safety" (22)
  • "pre-fire planning" (57)
  • "Safety Week" (13)
  • "Situational Awareness" assessment (72)
  • 911 (3)
  • Abandoned (3)
  • accident (1)
  • advocate (16)
  • Alert (1)
  • Architectural Design (15)
  • Arson (2)
  • assemblies (19)
  • behaviors (11)
  • Black Sunday (2)
  • Bronx (1)
  • Brooklyn (5)
  • building construction (185)
  • Building Construction for the Fire Service (182)
  • Building Construction for the Fire Srvice (6)
  • buildings (116)
  • buildingsonfire.com (202)
  • Charleston (5)
  • Christopher Naum (241)
  • close-call (25)
  • Codes (11)
  • Collapse (66)
  • Combat Fire Engagement (75)
  • command (4)
  • command presence (12)
  • command-leadership (28)
  • Company (8)
  • compentencies (43)
  • construction (97)
  • country (1)
  • courage (5)
  • courage to be safe (28)
  • culture (5)
  • decision-making (51)
  • decisions (3)
  • deconstrucion (1)
  • Deconstruction (2)
  • demolition (1)
  • Deployment (13)
  • destiny (4)
  • development (2)
  • Disaster Response (3)
  • duty (3)
  • dynamics (16)
  • education (11)
  • EGH (5)
  • Engineered (7)
  • Engineered Structural Systems (21)
  • engineered systems (9)
  • events (7)
  • explosion (8)
  • failures (28)
  • Fatalities (15)
  • FDIC (2)
  • FDNY (26)
  • FEMA (1)
  • fire behavior (77)
  • fire chief (1)
  • Fire Flow (6)
  • Fire Protection Engineering (15)
  • fire service (16)
  • Fire Service Tradition (22)
  • fire suppression (82)
  • fire-prevention-education (4)
  • fire-rescue-topics (11)
  • firefighter (21)
  • Firefighter Memorial Weekend (2)
  • firefighter-safety-health (77)
  • firefighting (43)
  • firefighting-operations (212)
  • fires (54)
  • first-due (25)
  • floors (20)
  • fortitude (9)
  • Future (1)
  • gas leak (4)
  • Generations (3)
  • hazards (6)
  • hazmat (1)
  • health (1)
  • high-rise (7)
  • Highrise (8)
  • History Repeating Event (31)
  • honor (14)
  • hydraulics (2)
  • IAFC (4)
  • IAFF (1)
  • in-the-line-of-duty (35)
  • incidents (3)
  • inspections (4)
  • leadership (6)
  • lessons (9)
  • line-of-duty (31)
  • LODD (84)
  • Lumber (8)
  • LVL (1)
  • major-incidents (32)
  • management (1)
  • Manufacturing (1)
  • mass-casualty-incident (6)
  • Mayday (30)
  • mentoring (4)
  • Multipl Alarm (2)
  • Naum (24)
  • near-miss (5)
  • NETC (1)
  • NFA (4)
  • NFFF (12)
  • NFPA (10)
  • NIOSH (30)
  • NIST (13)
  • NMRS (4)
  • occupancies (27)
  • Officers (3)
  • operations (12)
  • ordinary (4)
  • placard (1)
  • Planning (2)
  • pre-planning (20)
  • professional development (17)
  • Protection (1)
  • qualifications (4)
  • Recommendations (5)
  • Remembrance (18)
  • Renovations (2)
  • Reports (14)
  • rescues (1)
  • research (22)
  • residential (12)
  • response (2)
  • risk (7)
  • risk-based assessment (35)
  • Risk-preferring (6)
  • RIT (6)
  • roof (3)
  • Safety (9)
  • Safety Culture (20)
  • scenario (2)
  • size-up (26)
  • Skills (7)
  • special-operations (3)
  • Sprinklers (6)
  • staffing (1)
  • standpipe (1)
  • statistics (5)
  • strategies (21)
  • structure fires (22)
  • study (3)
  • survival (2)
  • symposium (2)
  • Systems (1)
  • Systems and Assemblies (5)
  • tactics (15)
  • Taking it to the Streets (12)
  • Technology (2)
  • technology-communications (1)
  • Ten Minutes in the Street (4)
  • timber (1)
  • Tpical Report Series (1)
  • tradition (6)
  • training (17)
  • training-development (30)
  • training-fire-rescue-topics (11)
  • Trapped (6)
  • Truss (6)
  • UL (3)
  • Uncategorized (150)
  • Urban Search and Rescue (1)
  • USAR (1)
  • USFA (9)
  • vacant (4)
  • ventilation (1)
  • volunteer (1)
  • Wind Driven (3)
  • Wind Driven Fires (2)
  • Wood Frame (1)
  • WTC (1)
  • Comments
    SFFD Diamond Heights LODD Safety Violations | Command Safety
    San Francisco FD: The Diamond Heights Fire Updates
    [...] San Francisco FD: The Diamond Heights Fire Updates [...]
    2011-12-03 09:06:40
    SFFD Diamond Heights LODD Safety Violations | Command Safety
    2nd San Francisco Firefighter Dies After Diamond Heights Fire
    [...] 2nd San Francisco Firefighter Dies After Diamond Heights Fire [...]
    2011-12-03 09:05:18
    The Worcester 6 | The Company Officer
    Worcester Cold Storage Warehouse Fire 1999
    [...] From last year’s posting and links at CommandSafety.com: HERE [...]
    2011-12-03 08:33:42
    Remembrance: Worcester Cold Storage Warehouse Fire and the Worcester Six | Buildingsonfire.com
    Worcester Cold Storage Warehouse Fire 1999
    [...] From last year’s posting and links here at CommandSafety.com: HERE [...]
    2011-12-03 07:51:28
    Remembrance: Worcester Cold Storage Warehouse Fire and the Worcester Six | Command Safety
    Worcester Cold Storage Warehouse Fire 1999
    [...] From last year’s posting and links here at CommandSafety.com: HERE [...]
    2011-12-03 07:47:31
    New Leaders: JFK's Nightmare
    New Leaders: JFK's Nightmare
    It's OK.
    It's OK.
    Welcome to the Club
    Welcome to the Club
    Author Unknown
    The Part We Forget
    The Part We Forget

    Christopher Naum's Discussions

    /* Removes Buzzboost Logo (MBT) */ div #creditfooter{ display: none; }
    Follow Chris Naum

    Mission Critical

    banner ad

    banner ad

    FirefighterNetCast on Blog Talk Radio

    Listen to internet radio with FirefighterNetCast on Blog Talk Radio

    The New Safety Formula: Bk = F2S

    Without understanding the building-occupancy relationships and integrating; construction, occupancies, fire dynamics and fire behavior, risk, analysis, the art and science of firefighting, safety conscious work environment concepts and effective and well-informed incident command management, company level supervision and task level competencies…You are derelict and negligent and "not "everyone may be going home". Our current generation of buildings, construction and occupancies are not as predictable as past conventional construction; risk assessment, strategies and tactics must change to address these new rules of structural fire engagement. There is a need to gain the building construction knowledge and insights and to change and adjust operating profiles in order to safe guard companies, personnel and team compositions. It's all about understanding the building-occupancy relationships and the art and science of firefighting, Building Knowledge = Firefighter Safety (Bk=F2S)

    Addressing Today’s Evolving Fireground

    Lectures,Seminars and Training Programs

    banner ad

    Taking it to the Streets Radio

    • banner ad
    • The Newest radio show on FireFighter Netcast.com at Blogtalk Radio… Taking it to the Streets with Christopher Naum. On the Air Monthly on Firefighter Netcast.com. A Buildingsonfire.com Series and Firefighter Netcast.com Production. Advancing Firefighter Safety and Operational Integrity for the Fire Service through provocative insights and dynamic discussions dedicated to the Art and Science of Firefighting and the Traditions of the Fire Service.

    QR Code for Commandsafety.com

    qrcode

    FireEMS Blogs eNewsletter

    Sign-up to receive our free monthly eNewsletter

    LATEST FIREFIGHTER NEWS

    HOT FORUM DISCUSSIONS

    LATEST ON FIRE ENGINEERING

    FEATURED DISCUSSIONS